Enhance your resilience, reliability, and operations.

Most overhead lateral faults are costly and avoidable. TripSaver reclosers bring smart fault management to your overhead distribution system to prevent unnecessary outages on blue-sky days and during severe weather.

TripSaver reclosers are designed to be simple to deploy and operate, with features that can help you reduce outages, speed restoration, and streamline your operations and budget.

Improve your fault response and unlock system-wide benefits with lateral automation.

Why Leading Utilities Choose S&C TripSaver Reclosers

Explore the advantages of S&C's single-phase reclosers.

With different ratings and designs to fit your unique system and workflow needs, TripSaver reclosers give you more flexibility and control to achieve your lateral automation goals.

Reduce outages and restore power faster. Up to 80% of faults on laterals are temporary. Smart fault management restores power automatically for temporary faults to avoid outages and isolates permanent faults with a drop-out function to minimize impact and accelerate restoration.

Install and integrate TripSaver reclosers easily using cutouts and extensive programmable curves that simplify device coordination. Crew-friendly features give you more operational control and efficiency.

Lower operating expenses with fewer truck rolls and manual interventions. TripSaver reclosers simplify system upkeep with less required maintenance and inventory.

Measure avoided outages and savings more easily, while gaining deeper grid visibility with device analytics and options like paired sensors.

Static photo of S and C's TripSaver FXR in simulation

Which TripSaver Recloser Model Is Right for You?

Explore our models to find the best fit for your system needs.

TripSaver Product Comparison

TripSaver® II Cutout-Mounted Recloser

Essential lateral automation for fast results.

Learn More

TripSaver® FXR Recloser

Next-level lateral automation: flexible, resilient, and an enhanced design.

Learn More

Summary

System class

15 kV, 25 kV
15 kV, 25 kV

Max voltage

15.5 kV, 29.0 kV
17.5 kV, 29.3 kV

Continuous current

40A, 100A, 200A
200A

Interrupting current

6.3 kA at 15.5, 29 kV
4.0 kA at 15.5, 29 kV
10.6 kA at 17.5 kV
8.0 kA at 29.3 kV

Weight

23 lbs (10.4 kg) for 15 kV
25 lbs (11.3 kg) for 25 kV
36.5 lbs (16.5 kg) for 15 kV
38 lbs (17.2 kg) for 25 kV

TCC library

200+ curves with fuse and hydraulic recloser emulations
200+ curves with fuse and hydraulic recloser emulations

Communications

Communications-ready with pole-mounted gateway
Communications-ready with modular design

Protection

Non-reclose mode
Sectionalizing mode
Sequence coordination
Inrush restraint
Non-reclose mode
Sectionalizing mode
Sequence coordination
Inrush restraint
Cold load pickup

Operation

Delayed close

Requires Cordless Power Module (Firmware v.2.1 or later)
Default capability

Status indicator

LCD screen
Semaphore & LED

Operating lever

One multi-function lever
Two dedicated, two position levers

Configuration

Settings development

S&C Service Center Configuration Software
TripSaver FXR Recloser Settings Web Application or plain-text file editor

Settings management

Managed with configuration software, stored locally
Managed with web-based settings application with option to store locally or in cloud

File transfer

Wireless connection via laptop with configuration software
Transfer to Data Module using FTP for automatic plug-in upload across many reclosers

Data Capture

Time stamping

Relative
Absolute

Data recorded

Device operations and standard event logs
Detailed event logs, system analytics, outage duration, fault waveform captures, and device statistics

Data access

Local retrieval via wireless laptop connection, remote retrieval via optional gateway and SCADA, configuration software required
Local retrieval via Data Module, no proprietary software required

Product Models

Savings Calculator

Pick a feeder on your system, and calculate how much you could save by using a TripSaver recloser.

Calculate

Pounds of CO2 Emissions TripSaver Reclosers Prevented This Year

*Calculated based on the U.S. Environmental Protection Agency Greenhouse Gas Equivalencies Calculator and utility-reported statistics for S&C’s TripSaver II recloser

How the TripSaver Recloser Has Helped Utilities

See how utilities around the world have reduced outage minutes and improved operational savings with TripSaver reclosers.

Bring the advantages of lateral automation to your system.