S&C Electric Company

Fault Fiter® Electronic Power Fuse

Product Literature

The publications listed below have been saved in Adobe® PDF format. To view them, you’ll need Adobe’s Acrobat® Reader® software, available for free download at Adobe’s website.


Descriptive Literature
Title Description

Descriptive Bulletin 441-30 (1 MB)

S&C Fault Fiter Electronic Power Fuses


Specifying and Ordering Information
Title Description

Specification Bulletin 441-31 (39 KB)

S&C Fault Fiter Electronic Power Fuses: Replacement Components


Application and Technical Information
Title Description

Data Bulletin 440-170 (44 KB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Series Coordination of Inverse-Current-Type Fault Fiter with Source-Side Induction-Disc Overcurrent Relays

Data Bulletin 440-171 (38 KB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Series Coordination of Inverse-Curve-Type Fault Fiters with Source-Side Solid-State Overcurrent Relays

Data Bulletin 440-175 (21 KB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Maximum Fault Current for Series Coordination of Inverse-Curve-Type Fault Fiters

Data Bulletin 440-176 (39 KB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Series Coordination of Inverse-Curve-Type Fault Fiters with Load-Side Power Fuses

Data Bulletin 440-177 (48 KB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Series Coordination of Inverse-Curve-Type Fault Fiters with Load-Side General-Purpose Current-Limiting Fuses

Data Bulletin 440-178 (58 KB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Series Coordination of Time-Delayed Compound-Curve Type Fault Fiters with Load-Side General-Purpose Current-Limiting Fuses

Data Bulletin 440-179 (44 KB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Series Coordination of Time-Delayed Compound-Curve-Type Fault Fiters with Load-Side Oil Immersible Partial-Range Current-Limiting Fuses

Data Bulletin 440-180 (23 KB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Series Coordination of Underground-Subloop-Type Fault Fiters with Load-Side Bayonet Weak-Link Fuses

Data Bulletin 440-210 (5 KB)

S&C Fault Fiter Electronic Fuses: Time-Current Characteristic Curves

Data Bulletin 441-50 (45 KB)

S&C Fault Fiter Electronic Power Fuses: Applications

Data Bulletin 450-115 (59 KB)

S&C Fault Tamer Fuse Limiters Supplement to Selection Guide for the Protection of Overhead Distribution Transformers

Data Sheet 440-192 (312 KB)

S&C Fault Fiter Electronic Fuses; Load-Pickup Capability

Data Sheet 440-215 (78 KB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Time-Current Characteristic Curves-Instantaneous Type (TCC No. 400-7)

Data Sheet 440-216 (2 MB)

S&C Fault Fiter Electronic Power Fuses Indoor Distribution (4.16 kV through 25 kV) Time-Current Characteristic Curves-Compound Type (TCC No. 420-7)


Instructions
Title Description

Instruction Sheet 441-520 (485 KB)

S&C Fault Fiter Electronic Power Fuses: Interrupting Modules and Control Modules (Installation)

Instruction Sheet 441-535 (492 KB)

S&C Fault Fiter Electronic Power Fuses: Disconnect Style (Operation)

Instruction Sheet 441-540 (805 KB)

S&C Fault Fiter Electronic Power Fuses: Disconnect Style with Uni-Rupter (Operation)


Reference
Title Description

Article Reprint 440-R79 (404 KB)

Electronic fuse improves protection, coordination by Arden E. Carr and Bill D. Wright

Article Reprint 440-R85 (824 KB)

Electronic fuses protect cable, network transformers

Technical Paper 440-T59 (618 KB)

Electronic Fuse Provides Improved Coordination on Medium-Voltage Distribution Systems by J.C. Gorman and C.J. Cook